ChemWifi - Quality control & Quality assurance guideline of Textile & Leather - A Blog about Textile & Leather product Testing Quality control , Quality assurance , Analytical Method Validation, SOPs, NABL Documentation, EIC, BIS, ISO/IEC 17025:2017, ASTM, Analytical Method Development, Eco Textile, Textile Chemistry, instrument calibration related information provideChemWifi - Quality control & Quality assurance guideline of Textile & LeatherChemWifi - Quality control & Quality assurance guideline of Textile & LeatherChemWifi - Quality control & Quality assurance guideline of Textile & Leather

A Blog about Textile & Leather product Testing Quality control , Quality assurance , Analytical Method Validation, SOPs, NABL Documentation, EIC, BIS, ISO/IEC 17025:2017, ASTM, Analytical Method Development, Eco Textile, Textile Chemistry, instrument calibration related information provide

  • Home
  • Testing
    • Leather Testing
    • Rubber Testing
    • Textile Testing
    • Thermal insulation
    • Water Testing
  • Standard Preparation
  • Uv Calibration
  • About us

Monthly Archives: June 2019

ChemWifi - Quality control & Quality assurance guideline of Textile & Leather > Blog Large Image > 2019 > June
08
Jun
Date June 8, 2019
Author Aman Kumar Sah

Determination of Water Soluble Matter – Textile materials

Water  Soluble Matter  SCOPEThis standard prescribes a method for determining the Water soluble matter of textiles. PR...
Read More
0 Comments Author Aman Kumar Sah
08
Jun
Date June 8, 2019
Author Aman Kumar Sah

Determination of Chromium content – Leather Materials

CHROMIUM OXIDE CONTENT WET OXIDATION METHOD APPARATUSDesiccator.Erlenmeyer flask – 300 ml capacityConical flask – with s...
Read More
0 Comments Author Aman Kumar Sah
07
Jun
Date June 7, 2019
Author Aman Kumar Sah

Resolution power ( Calibration of UV-Spectrometer ) – Toluene

Resolution power 0.02 % ( v/v ) Toluene solution Take 20 μl of Toluene and dissolve & make up to 100 ml with Hexane....
Read More
0 Comments Author Aman Kumar Sah
07
Jun
Date June 7, 2019
Author Aman Kumar Sah

Limit of Stray Light KCL ( Calibration of UV-Spectrometer ) – KCL

Limit of Stray Light Potassium Chloride Solution Weight accurately 1.2 gm of Potassium chloride (previously dried at 105 o&nb...
Read More
2 Comments Author Aman Kumar Sah
07
Jun
Date June 7, 2019
Author Aman Kumar Sah

Photometric Accuracy ( Calibration of UV-Spectrometer ) – KNO3

Photometric Accuracy Potassium Nitrate  solutionPrepare 1.065 % w/v. 0.710 % w/v, 0.355 % w/v solution of Potassium Nitr...
Read More
0 Comments Author Aman Kumar Sah

Categories

  • Calibration
  • Chemistry
  • Forensic science
  • formula
  • GC-MS
  • GC-MS Calibration
  • Gemological
  • Handling
  • HPLC
  • ISO 17025
  • Leather Testing
  • Method validation
  • Plastics
  • Rubber Testing
  • Scientific
  • Standard Operating Procedure
  • standard preparation
  • Testing
  • Textile Testing
  • Thermal insulation
  • Uv Calibration
  • Water Testing

Recent Posts

  • Preparation of Bleaching PowderJanuary 17, 2023
  • Preparation of PhenolJanuary 17, 2023
  • How to prepare 5% potassium persulphate?January 17, 2023
  • Standard Operating Procedure(SOPs) for UV-Vis SpectrophotometerJanuary 17, 2023
  • ISO/IEC 17025:2017January 17, 2023

Tags

Biochemistry research Chemistry equipment‎ Medical Physics scientific research
ChemWifi - Quality control & Quality assurance guideline of Textile & Leather

USEFUL LINKS

  • About us

OUR SERVICES

  • Chemistry

RECENT POST

  • Preparation of Bleaching Powder January 17, 2023
  • Preparation of Phenol January 17, 2023
[mc4wp_form id="139"]
Copyright © 2025 ChemWifi. All rights reserved.